Main features & overview

01 dlc

Overview

Pancake like diaphragm load cell designed for the use in Fully electric Injection Molding Machines.

The Flat-Body design allows for easy integration into the injection unit without adding to the machine length.

Available with standardized mV/V output or an EEPROMModule to allow for higher mV/V-Output for better signal/noise ratio (to be used with special VDA-Amplfier).

High-grade steel for endless cycles and optional amplifer necessary.

Description

Main features

  • FLAT-body design
  • Good linearity
  • Designed integrate into machine
  • With EEPROM for sensitivity detection (option)

Main features & overview

02 dlca

Overview

Pancake like diaphragm load cell designed for the use in Fully electric Injection Molding Machines.

The Flat-Body design allows for easy integration into the injection unit without adding to the machine length.

Description

Main features

  • FLAT-body design
  • Good linearity
  • Designed integrate into machine

Main features & overview

01 sb

Overview

The principle of measurement of the SH series load cells is the deformation caused by the shear generated by the applied load.

The result is a transducer that is extremely rigid both for the measured load and of lateral or transverse loads which have little effect on it.

The high degree of accuracy, good level of thermal compensation, the grade of protection make the SH series load cells safe for use in the most severe conditions.

Description

  • Range of measurement: from 500 to 10,000 Kg
  • Accuracy class: D1 (OIML IR60)
  • All stainless steel construction
  • Corrosion resistant
  • Insensitive to lateral loads
  • Grade of protection: IP66 (DIN 40050)

Main features & overview

02 sh

Overview

The principle of measurement of the SH series load cells is the deformation caused by the shear generated by the applied load.

The result is a transducer that is extremely rigid both for the measured load and of lateral or transverse loads which have little effect on it.

The high degree of accuracy, good level of thermal compensation, the grade of protection make the SH series load cells safe for use in the most severe conditions.

Description

  • Range of measurement: from 500 to 10,000 Kg
  • Accuracy class: D1 (OIML IR60)
  • All stainless steel construction
  • Corrosion resistant
  • Insensitive to lateral loads
  • Grade of protection: IP66 (DIN 40050)

Main features & overview

01 cb

Overview

  • Range of measurement: from 20 to 200 Kg
  • Accuracy class: C (OIML IR60)
  • All stainless steel construction
  • Corrosion resistant
  • Grade of protection: IP67 (DIN 40050)

Description

CB series load cells are designed for trouble free application in industrial environments.

The cell body and the protective bellows of the strain gauge are in corrosion resistant stainless steel and the bellows are welded using microplasma torch.

CB load cells are supplied in three grades of accuracy and characteristics.

The 1000 division is the most economical and suitable for most applications.

The 2000 division version has a good price/performance ratio.

The 3000 division is available if higher accuracy is required.

CB load cells are used in particularly hostile enviroments in the food, petrochemical and pharmaceutical industries and in all applications that demand components in stainless steel and IP67 grade of protection.

Main features & overview

02 tr

Overview

TR series force transducers are used to measure the tension that plastic films or tapes exert on the guide rollers of the machinery used to coil them.

Mounted at the ends of a fixed or transmission shaft on the machine chassis, they perform the function of force sensors and bearing for the ends of the shaft.

They are used on both fixed and rotating shafts.

TR transducers are supplied with the adaptor flange for fixing, with 4 M6 screws or with one central M10 or M12 screw.

Description

  • Range of measurement: from 100N to 2kN
  • Accuracy class: 0.5%
  • Corrosion resistant
  • Internally generated calibration signal
  • Orientation of the axis of maximum sensitivity for 35° independently from
  • the position of the fixing holes
  • Grade of protection: IP65 (DIN 40050)
  • Integrated protection against overloads

Main features & overview

02 cir d

Overview

  • Linearity error < 0.02% FSO
  • Voltage or current output
  • Low thermal drift < 0.01% FSO/°C
  • Compact size

Description

The CIR voltage or current amplifiers have been designed to enable the user to adapt non-amplified strain gauge transducers (load cells, pressure transducers) to acquisition systems, PLC, instrumentation with high level inputs.

The availability of the output in voltage or current enables the signal to be carried over long distances or used in intelligent automation systems

Main features & overview

01 cir

Overview

  • Linearity error < 0.02% FSO
  • Voltage or current output
  • Low thermal drift < 0.01% FSO/°C
  • Compact size

Description

The CIR voltage or current amplifiers have been designed to enable the user to adapt non-amplified strain gauge transducers (load cells, pressure transducers) to acquisition systems, PLC, instrumentation with high level inputs.

The availability of the output in voltage or current enables the signal to be carried over long distances or used in intelligent automation systems